System Specifications
Functional data Equipment type · Electro sensitive protective equipment according to EN 954-1 class 4. · The development and certification according to EN 12622/61508 1-7/61496 1-2. · TÜV approval number: 78/205/550657
Level of protection · IP54
Protective functions · Detection of obstacles in the area under the punch · Surveillance of: - Mute point position - Slow mode feedback - Overrun distance - Fast approach speed - Slow speed - Mute indication
Optical range · +/- 6m
Vertical range · Auto-punch detection up to 35mm
Response time · 30ms (worst case)
Maximal acceptable fast approach speed · 200mm/s
Laser classification · Class 1M according to EN 60825-1
Input contacts for slow speed detection and box mode must comply to EN954 Category 4 Overrun distance selectable according to press brake type (max 10mm)
Environmental data Ambient operating temperature · 0 to 50°C
Storage temperature · -20 to 70°C
Humidity Class · In accordance with EN 61496-1
Electrical data Supply voltage · 230V/50-60Hz/0.25A · 30V DC ± 25% / 0.3A
Load conditions and contact impedances of OSSDs · Maximal current through load: 3A (switch voltage must be fused) · Max. Voltage over load: 48V DC/AC (load supply must be grounded) · Min. Open contact impedance OSSD: 10MΩ
Load on transistor outputs · 50mA/24V DC
Input contacts for slow speed detection must comply to EN954 Category 4
|


|
Robosoft nv Industriezone Noord Rozendaalstraat 6 8900 IEPER (Belgium)
Tel.: (+32) 57/21 94 57 Fax: (+32) 57/21 93 56 |