System Specifications

 

 

Functional data

Equipment type

· Electro sensitive protective equipment according to EN 954-1 class 4.

· The development and certification according to EN 12622/61508 1-7/61496 1-2.

· TÜV approval number: 78/205/550657

 

Level of protection           

· IP54

 

Protective functions

· Detection of obstacles in the area under the punch

· Surveillance of:

            - Mute point position

            - Slow mode feedback

            - Overrun distance

            - Fast approach speed

            - Slow speed

            - Mute indication

 

Optical range

· +/- 6m

 

Vertical range

· Auto-punch detection up to 35mm

 

Response time

· 30ms (worst case)

 

Maximal acceptable fast approach speed

· 200mm/s

 

Laser classification

· Class 1M according to EN 60825-1

 

Input contacts for slow speed detection and box mode must comply to EN954         Category 4

Overrun distance selectable according to press brake type (max 10mm)

 

Environmental data

Ambient operating temperature

· 0 to 50°C

 

Storage temperature

· -20 to 70°C

 

Humidity Class

· In accordance with EN 61496-1

 

Electrical data

Supply voltage                 

· 230V/50-60Hz/0.25A

· 30V DC ± 25% / 0.3A

 

Load conditions and contact impedances of OSSDs

· Maximal current through load: 3A (switch voltage must be fused)

· Max. Voltage over load: 48V DC/AC (load supply must be grounded)

· Min. Open contact impedance OSSD: 10MΩ

 

Load on transistor outputs

· 50mA/24V DC

 

Input contacts for slow speed detection must comply to EN954 Category 4

 

Principal operation

 

General safety functions

 

Why choose for SafFir

SafFir headerTUV logoCE logo

Robosoft nv

Industriezone Noord

Rozendaalstraat 6

8900 IEPER (Belgium)

 

Tel.: (+32) 57/21 94 57

Fax: (+32) 57/21 93 56

robosoft@westhoek.be

Info Robosoft